ENC INVERTER
Keyboard:
EN-KB1 (Local keyboard for EDS2000)
EN-KB3 (Romote-control keyboard for EDS2000)
EN-KB5 (Small local keyboard for EDS800/EDS1000 below 2.2KW (included))
EN-KB6 (Local keyboard for EDS1000 above 3.7kw (included))
The distance between inverter and EN-KB3 can reach 1000 meters maximally.
Our inverters support local keypad and long distance keypad synchronously,
no priority, you can operate the inverter through both of them at the same time.
EN-KB8(Romote-control keyboard for EDS1000,Modbus protocol)
EN-KB16(Romote-control keyboard for EDS1000,profitbus protosol)
EN
-
KB5keyboard
EN
-
KB1 keyboard
Digital display (LED)
Mode indicator light
Reverse run indi cat
e
light
Analog potentiometer
Forward run indicate light
Failure alarm indicate light
Displayed frequency unit (Hz)
Displayed current unit (A)
Joy key
Shift/
Supervision key
Confirm/Data key
Program/Exit key
Stop/Rest key
Run key
Displayed voltage unit (V)
keyboard extending and hole size :
EDS2800 series inverter
Have all the features of EDS2000 series
Full load output at Low-frequency (0.1Hz).
With powerful over load ability--- 150% of rated current 3 minutes, 200% of rated current 5 seconds.
Perfect control function for injection molding machine.
Provide 2-way 0-1A and 2-way 0-10V isolated analog input signal channels
Effective control of the excitation current can control the heating of injection molding machines effectively
Power range: 11KW~75KW 3phase 380V
EDS2080 series bypass/variable frequency integrated energy save and control machine
Have all the features of EDS2000 series
Bears automatic voltage regulation (AVR) and automatic current limiting function
Power source/Variable frequency dual-loop operation with automatic reset,
power-off reset function
Be able to retain the original loop system
Can add isolating switch, breaker/ fuse, AC input / output reactors,
input / output EMI filters and other accessories according to customers' need.
Can add ammeter, voltmeter, cymometer and etc. according to customers' need.
Power range:3phase 380V 7.5KW~400KW
Mounting dimension figure for constant pressure water supply controller:
Adaptable type: EDS2860-4T0075-EDS2860-4T0750
88±0.10
153±0.10
Spare parts selection
Keyboard extending holder 1
Hole size for holder 1
(3.7kw and above)
Keyboard extending holder 2
Basic control wiring diagram
17
18
R
S
T
W
V
U
KM2
W
V
U
E
COM
FWD
1I
1C
2I
2C
21
22
KM2
0-1A
0-1A
Common 1
Common 2
Run signal
Flux signal
Pressure signal
R
T
S
KM1
Option switch
Power save
Stop
01
06
KM1
KM2
07
05
04
LED2
LED1
KM1
11
10
9
8
KM2
Variable
frequenc
y
Power
source
uk
vk
wk
uo
vo
wo
pe
02
03
v
w
u
12
Power source
Connect terminal
Power 380V
50/60Hz
Motor
connect
termial
Ground
wire
termianl
Remarks:
For control functions of EDS2860 series, please refer
to EDS2800 series manual.
Constant pressure
water supply
controller
Extending wire for KB5
Holder 1 and wire Holder 2 and wire
Holder and wire for
remote-control keyboard
88
153
Hole size for holder 2
(3.7kw and above)
Hole size for Kb5
Analog potentiometer
Joy key
Shift/
Supervision key
Reverse run indicat
e
light
Forward run indicate light
Displayed frequency unit (Hz)
Displayed current unit (A)
Displayed volt age unit (V)
Digital display (LED)
Mode indicator light
Failure alarm indicate light
Confirm/Data key
Program/Exit key
Stop/Rest key
Run key
Date change key
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14

Comentarios a estos manuales

Sin comentarios